MDM Trouble Report for 2002 Jan 20 Telescope: 2.4m Observer(s): John Thorstensen (Dartmouth.) Instrument: modspec+echelle Problem(s) Encountered: The squealing and jumping in RA which occurred from time to time last night appear to have cured themselves for the time being. No idea why! I had two real problems and one operator error which looked like a terrible problem for a while. Real problems: (1) The CCD reset itself during an integration or readout. The message was electronics appear to be in cold reset state and the chip format was altered. I just did df echelle, ut init, reset the format, and that was that. I did lose a short integration. There was no apparent cause. (2) The slit-viewing optics slipped again. I fixed it by pushing it back in. Then the manmade problem: When rotating the spectrograph to the parallactic angle, I snagged the power cord which feeds the TV cameras, the CCD controller, and perhaps other equipment. I first noticed this when the TV wouldn't show anything at all. This made me think something had gone wrong with some part of the TV equipment, so I tried various tests (feeding the video from the camera right into the monitor, etc) but nothing worked. For about 40 terrible minutes I thought the rest of the weekend was lost, but I eventually noticed that none of the red lights on the various power supplied on the rotator were lit, and then I quickly figured it out. Lost rather more than an hour. ------------------------------ Submitted on 2002 Jan 20 [7:30:55]