MDM Trouble Report for 2005 Jun 28 Telescope: 2.4m Observer(s): J. Thorstensen, H. Sheets (Dartmouth) Instrument: Modspec + echelle CCD Problem(s) Encountered: Two glitches: 1) CCD electronics lost it during first integration of the night; error was ccd_aread: wrong aio finished; expected 0. This is bad. *** Error encountered in asynchronous read, data suspect Failed, error code = 0, elapsed = 2.023000 The cure was simply to push the red reset button on the camera electronics, type df echelle , re-enter the format numbers, and go. 2) On two occasions the telescope glitched during setting; the symptom was a 30-arcsec oscillation in RA over a roughly 2-second cycle time; I could hear the drive engaging and disengaging. The cure was to hit the soft stop button in xtcs3, move the telescope near the object with the paddle, and hit go again. This does not appear to be a mechanical problem with the drive, and is clearly distinct from the more serious jump-and-stall issue that occurs with temperature changes. This looks like a software issue. ------------------------------ Submitted on 2005 Jun 29 [5:26:16]