MDM Trouble Report for 2013 Jun 06 Telescope: 2.4m Observer(s): John Thorstensen (Dartmouth) Instrument: Modspec + Templeton Problem(s) Encountered: Twice during the afternoon, Owl started giving nonsense data -- all zeros. Once was when I was starting to set up the spectrograph, after the controller had been idle for a while, and the other time was in the middle of a sequence of flat fields. Failure was silent - the images just started coming up blank without an error message. I could get going again by running the Owl Setup (i.e., re-loading the code into the controller, etc) and re-loading my subarray format. I think this was caused by high ambient temperature affecting the Leach electronics. Paul set up the big fan to blow air over the controller box from a distance, and I didn't have any trouble after that. It did not recur during the night, when it was much cooler than the afternoon of course. ------------------------------ Submitted on 2013 Jun 7 [5:22:25]