MDM Trouble Report for 2016 Jul 04 Telescope: 2.4m Observer(s): R. M. Wagner (OSU) Instrument: OSMOS Problem(s) Encountered: 1. IQ issues. Coma + trefoil at the start of the night. Trefoil went away so it could have been a thermal issue. Coma persisted and was obvious during focus sequences. 2. Dome following failed. Same issue as reported by the observers from June 27-28. At one point I put the dome back to 320 and cycled the dome power without moving the telescope. The dome slewed right to the telescope after that but still would not track. I moved it manually all night. I will add that the dome failed to arrive at the telescope on the initial slew to the target that was 4h E at +30 Dec. 3. When I closed the vent doors, I noticed that the RA drive was still running even though both the RA tracking and drives were off. I re-enabled the drives switch and the telescope began to slew. I turned it back off. Inspection of the RA motor then showed that it had turned off. I re-zeroed the telescope with the RA leveler. ------------------------------ Submitted on 2016 Jul 5 [4:41:58]