MDM Trouble Report for 2018 Nov 12 Telescope: 1.3m Observer(s): Bakowska (MDM Observatory) Instrument: Andor (Direct) Problem(s) Encountered: This is Eric submitting a report for last night. Telescope would not move in declination. Had the 2.4m observer cycle the dec controller but the problem remained. This morning, I found that the +24V in the TCS box to run the motor was not there. Verified that the +24V was at the other end, in the RA drive enclosure. This pointed to an issue with the pin/cable. Pulled the wire for the signal at both ends and ran a singular wire from the dec controller TB to the connection in the TCS electronics. Verified the presence of the +24 and verified telescope functionality. This is a robust enough (if also ugly) fix, but eventually a new connector will be pinned and installed. ------------------------------ Submitted on 2018 Nov 13 [12:59:33]