MDM Trouble Report for 2018 Aug 13 Telescope: 2.4m Observer(s): Rupert (MDM) Instrument: OSMOS/B Problem(s) Encountered: I think there is something to do with the temperature- dependent focus shift that messes with the dome's ability to track the telescope. A couple of nights ago, I tried using this now-working feature of the TCS. While slewing to a new target, the dome would stop, then start on its way again, and repeat this several times. It then overshot it's target position, stopped, then came back. I turned off the focus feature, and it didn't happen again. Tonight, I tried using that focus feature again, and while taking an exposure, the dome started moving. I disabled the focus feature while the dome was moving to who knows where. It eventually stopped and made its way back to the telescope position. I didn't enable the focus feature again, and there were no issues with the dome after. Hmmmm... ------------------------------ Submitted on 2018 Aug 14 [4:30:10]