MDM Trouble Report for 2022 May 04 Telescope: 1.3m Observer(s): Weil (Purdue) Instrument: Templeton Problem(s) Encountered: Upon opening the telescope for the night the TCS showed Telescope Tilt Sensor Interlock Engaged. Eric drove up the mountain to diagnose and fix the problem which was a blown fuse in the TCS electronics related to the interlock circuit. However once this problem was fixed the telescope would not slew. Eric was still on the mountain and attempting to fix the issue by first manually slewing the telescope, but found the telescope would not move in declination. Eric was not able to fix the problem during the night as a dec drive flip and rebooting the TCS did not fix the problem. Due to dust in the air and the late hour the entire night was declared a loss. Thank you Eric for coming up the mountain to fix these problems and give us some chance to observe. ------------------------------ Submitted on 2022 May 4 [22:22:35]